The external graphic display terminal is designed only for commissioning drives.
1 Display field
2 Navigation button
3 STOP/RESET key
4 RUN key
5 FWD/REV key
6 ESC key
7 Function keys F1 ... F4
Depending on the firmware version of the external graphic display terminal, the information may be represented differently. Use the most up-to-date firmware version.
The display is subdivided into 5 areas.
Display of the graphic display terminal (example shows English language)
1.1 Status information of the drive
1.2 Menu bar
1.3 Data field
1.4 Function bar
1.5 Navigation
This line displays the operating state, the actual velocity and the actual current of the motor. If an error has been detected, the error code is displayed.
The following information can be displayed and values entered in the data field:
Submenus
Operating Mode
Parameters and parameter values
State of movement
Error messages
The function bar displays the name of the function that is triggered when you press the corresponding function key. Example: Pressing the F1 function key displays the "Code". If you press F1, the HMI name of the displayed parameter is shown.